C) WORKING PRINCIPLE
Diapositiva successiva
Diapositiva precedente
- When the LPG temperature is higher than a pre-setted value and a fixed RPM value is reached the engine switches from petrol to LPG,
- Security solenoid valves are activated.
- Petrol injectors are deactivated.
-
- Electronic control unit Lo.G.I.C.® :
- Obtains the injectors opening time signal, coming from the original petrol E.C.U.,
- Obtains the ‘‘lambda’’ probe signal,
- Calculates the opening steps of the stepper-motors.
-
- The reducer / vaporiser Lo.G.I.C. ® :
- Reduces the LPG pressure and vaporises the liquid LPG coming from the tank,
- Regulates the LPG flow by the stepper-motor.
-
- The distributor Lo.G.I.C. ®:
- Keeps the LPG pressure on a constant value,
- Provides pneumatically each cylinder its proper LPG quantity.
-
-
-